Lighting Technologies & Controls: Solutions - WELL Services & Solutions - Lighting Services

Power Tuning lighting services and solutions to achieve the WELL standards and certification for the lighting features

WELL Standards & Certification - Power Tuning Lighting Design & Technical Support

Explore our lighting design services, technical support and reporting for acheiving the WELL v1 & v2 standards' lighting features.

LIHGTING

DESIGN &

TECHNICAL

SUPPORT

warmdim dynamic architechural lighting design
Lighting Features of v1
Design & Technical Support By Power Tuning
VISUAL LIGHTING DESIGN

1 - Lighting layout design & Lux calculation reports, on-site measurement reports and drawings layout luxlevels indicating special areas lux levels acheived.

2- Uniformity reports and drawings layout luminance levels for visual balance, and verification of brightness management strategies.

CIRCADIAN LIGHTING DESIGN
3- Lighting simulation with / without daylighting, with calculations reports for Equivalent Melanopic Lux (EML); based on computerized calculations and on-site measurement.
ELECTRIC LIGHT GLARE CONTROL

4- Choosing the appropriate lighting fixtures and calculating its shielding angle (α).

5- Luminance (cd/m2) & Glare (UGR) calculations through accurate computerized simulations.

SOLAR GLARE CONTROL
6- Daylighting simulation using shadings, reflectors or special glass parameters to view their effect on the interiors, with glare calculations.
LOW-GLARE WORKSTATION DESIGN
7- Choosing the appropriate lighting fixture and indicating its luminous curve aiming rays in vertical plan section for the workstation.
COLOR QUALITY

8- Report of average the Colour Rendering Index (CRI) of each space.

SURFACE DESIGN
9- Lighting simulation report indicating the reflectance values of ceiling, walls & furniture as per actual values.
AUTOMATED SHADING AND DIMMING CONTROLS

10- Sensors choosing and layout design.

11- Design automated control system with occupancy and Lux leveling sensors.

RIGHT TO LIGHT
------
DAYLIGHT MODELING
12- Daylight simulation calculations for spaces and floors, and report of Spatial Daylight Autonomy (sDA) & Annual Sun Exposure (ASE) of all areas.
DAYLIGHTING FENESTRATION
------
LIGHT AT NIGHT

13- Choosing of fixtures and design of Nightlight Safe Pathes with sensor controlled.

14- Design, implementation and adjusting of the automation system for night mode controlling shades, lighting systems, etc. And providing a print out report for these functions.

CIRCADIAN EMULATION
15- Design, implementation and adjusting of the circadian lighting system, with EML calculations as per service no.3.
Lighting Features of v2
Design & Technical Support By Power Tuning
LIGHT EXPOSURE & EDUCATION

1 - Daylight simulation calculations for spaces, and report of Spatial Daylight Autonomy (sDA) of all areas.

2- Educational presentations and training on Lighting & Health, and providing the training file including objectives and materials.

VISUAL LIGHTING DESIGN

3- Lighting layout design according to the specified guidelines & Lux calculation reports, on-site measurement reports and drawings layout luxlevels indicating tasks and age ranging majority of each area.

CIRCADIAN LIGHTING DESIGN
4- Lighting simulation with / without daylighting - for the specified day-hours, with calculations reports for Equivalent Melanopic Lux (EML); based on computerized calculations and on-site measurement.
GLARE CONTROL

5- Daylighting simulation and calculations of the Annual Sunlight Exposure (ASE) with the using shades, windows reflectors or special glass parameters to view their effect on the interiors, with glare calculations.

6- Design, implementation and adjusting of the automation system with weekly scheduling functions for controlling shades, lighting systems, etc. And providing a print out report for these functions.

7- Choosing the appropriate lighting fixtures and calculating its shielding angle (α).

8- Luminance (cd/m2) & Glare (UGR) calculations through accurate computerized simulations.

ENHANCED DAYLIGHT ACCESS - Same as Service (1)
VISUAL BALANCE

9- Uniformity reports and drawings layout luminance levels for visual balance, and verification of brightness management strategies for all surfaces and between areas.

10- Adjusting of the lighting control or automation system dimming strategies for the smooth transition as specified, and providing a print out report for these functions.

ELECTRIC LIGHT QUALITY

11- Report of average the Colour Rendering Index (CRI) or R1-R9 or TM30 - as per the available data from the lighting fixtures datasheets of the manufacturer of each space.

12- Choosing and inspection of drivers used to acheive the required performance for of acceptable flickering.

OCCUPANT CONTROL OF LIGHTING ENVIRONMENTS

13- Design, implementation and adjusting of the circadian lighting system, integrated with lighting control system (Service No. 6), with needed occupants assignments for manual or overrides, and providing a print out report for these functions.

14- Choosing of scalable lighting layouts, systems and controls, with reports of how can we double the lighting levels as per figures designed in service no.3.

 

Power Tuning Lighting Solutions for WELL Certificate

Check our Lighting Solutions dedicated for WELL Certificates

 

For more technical information of systems and applications, click here to contact us